Parameter
|
Instrument Type
|
Manufacturer or Provider
|
Range (and error)
|
Total air temperature |
Platinum wire resistance |
Rosemount Model 102CY2CG and 414 L Bridge |
-60 to 40°C (< 0.1°C) |
Static air temperature |
Reverse-flow thermometer |
In-house |
-60 to 40°C (< 0.5°C) |
Dew point |
Cooled-mirror dew point |
Cambridge System Model TH73-244 |
-40 to 40°C (< 1°C) |
Absolute humidity |
IR optical hygrometer |
Ophir Corp. Model IR-2000 |
0 to 10 g m-3 (~5%) |
Air turbulence |
RMS pressure variation |
Meteorology Research, Inc. Model 1120 |
0 to 10 cm2/3 s-1 (<10%) |
UV hemispheric radiation, one one downward |
Diffuser, filter photo-cell (0.295 - 0.390 um) |
Eppley Lab. Inc. Model 14042 |
0 to 70 W m-2 (+/- 3 W m-2) |
VIS-NIR hemispheric radiation (one downward and one upward viewing) |
Eppley thermopile (0.3 - 3 um) |
Eppley Lab. Inc. Model PSP |
0 to 1400 W m-2 (+/- 10 W m-2) |
Surface radiative temperature |
IR radiometer 1.5° FOV (8 to 14 um) |
Omega Engineering Model OS3701 |
Variable: -50°C to 1000°C (~1% of reading in °K)
|
Video image |
Forward looking camera and time code |
Sony Hi8 camera |
VHS tape |
Parameter
|
Instrument Type
|
Manufacturer or Provider
|
Range (and error)
|
Liquid water content |
Hot wire resistance |
Johnson-Williams |
0 to 2 and 0 to 6 g m-3 |
Liquid water content |
Hot wire resistance |
King/PMS |
0 to 5 g m-3 |
Liquid water content; particle surface area; effective droplet radius |
Optical sensor |
Gerber Scientific Inc. PVM-100A |
0.001-10 g m-3; 5-10,000 cm2m-3; 2-70 um |
Size spectrum cloud particles |
Forward light-scattering |
Particle Measuring Systems FSSP-100X |
2 to 47 um [*] |
Size spectrum of precipitation particles |
Diode occultation |
Particle Measuring Systems OAP-200X |
20 to 300 um [*] |
Images of cloud particles |
Diode occultation imaging |
Particle Measuring Systems OAP-2D-C |
25 to 800 um [*] (resolution 25 um)
|
Images of precipitation particles |
Diode imaging |
Particle Measuring Systems OAP-2D-P
| 100 to 3200 um [*] (resolution 100 um)
|
Parameter
|
Instrument Type
|
Manufacturer or Provider
|
Range (and error)
|
Number concentrations of particles |
Water expansion cloud chamber |
General Electric Model CNC I |
10 to 3 x 105 cm-3 (particles > 0.01 um)
[*] |
Number concentrations of particles |
Butanol continuous flow diffusion chamber |
TSI Model 3760 CNC III |
10-2 - 2 x 104 cm-3 (>0.003 um) |
Cloud condensation nucleus spectrometer [+]
|
Vertical-plate continuous flow thermal diffusion cloud chamber |
In-house |
Four supersaturations, between 0.2 and 2% |
Size spectrum of particles [+] |
90° light-scattering |
Particle Measuring Systems Model LAS-200 |
0.5 to 11 um [*] |
Size spectrum of particles |
Forward light-scattering |
Particle Measuring Systems Model FSSP-300 |
0.3 to 20 um [*] |
Size spectrum of particles [+] |
35 to 120° light-scattering |
Particle Measuring Systems Model ASASP-100X |
0.18 to 3.0 um [*] |
Size spectrum of particles |
Forward light-scattering |
Particle Measuring Systems Model FSSP-100 |
2 to 47 um [*] |
Size spectrum of particles |
Passive Cavity Scattering |
Particle Measuring Systems Model PCASP 100-X |
0.1 to 3.0 um [*] |
Size spectrum of particles [+] |
Differential Mobility Particle Sizing Spectrometer (DMPS) |
In house (using TSI Model 3025 CN counter) |
0.01 to 0.6 um [*] |
Light-scattering coefficient |
Integrating nephelometer |
Meteorology Research, Inc. Model 1567 (modified for increased stability
and faster response time) |
1.0 x 10-5 to 2.5 x 10-3 m-1 |
Light-scattering coefficient [+] |
Integrating nephelometer |
Radiance Research |
1.0 x 10-6 m-1 to 2.0 x 10-4 m-1 or 1.0 x 10-6 m-1 to 1.0 x 10-3 m-1
|
Light-scattering coefficient |
Integrating 3-[[lambda]] nephelometer with backscatter shutter |
MS Electron |
1.0 x 10-7 to 1.0 x 10-3 m-1 for 550 and 700 nm channels. 2.0 x 10-7
to 1.0 x 10-3 m-1 for 450 nm channel. |
Light-scattering coefficient (Operating continuously in the OEC on
clear air and plume samples.) |
Integrating nephelometer |
UW Civil Engineering |
10-7 to 10-2 m-1 at 537 nm |
Particle humidification factor [+] |
Particle light scattering vs. humidity |
Mark Rood (In-house) |
With 40 lpm of air stream, allows RH to increase from 29-85% in 4:45
|
Light-extinction coefficient of smoke
[+] |
Optical extinction cell OEC (6m path length) |
Waggoner Electronics |
5 x 10-5 to 10-2 m-1 |
Light absorption and graphitic carbon |
Particle soot/absorption photometer |
Radiance Research |
Absorption coefficient: 10-7 to 10-2 m-1; Carbon: 0.1 ug m-3 to
10 mg m-3 (+/- 5%) |
Aerosol-shape asymmetry analyzer
[+] |
Change in light-scattering measurements with applied electric field
|
Radiance Research |
Detects ~2% deviations from sphericity |
Graphitic and/or Organic Carbon
[+] |
Quartz filters Thermal optical technique |
Catherine Liousse |
>4 ug m-3 (+/- 1.6 ug m-3) for 1m3 sample |
Parameter
|
Instrument Type
|
Manufacturer or Provider
|
Range (and error)
|
Particulate species [+]
SO=4, NO-3, Cl-,
Na+, K+, NH4+,
Ca++, Mg++ |
Teflon filters Ion exchange chromatography |
Gelman Dionex |
0.1 to 50 ug m-3 (for 500 liter air sample) |
SO2 |
Pulsed fluorescence |
Teco SP43 (modified in-house) |
1.0 ppb to 5 ppm |
Hydrocarbons, CO, CO2 [+] |
Collected in stainless steel canisters, analysis by GC/FID |
U.C. Irvine |
Variable |
Ozone |
Chemi-luminescence (C2H4) |
Monitor Labs Model 8410 A |
0 to 5 ppmv (< 7 ppb) |
NO, NO2, NOx |
Chemi-luminescence (O3) |
Modified Monitor Labs Model 8840 |
0 to 5 ppmv (~1 ppb) |
CO |
Infrared correlation spectrometer |
Teco Model 48 |
0 to 50 ppmv (~0.1 ppmv) |
CO2 |
Infrared correlation spectrometer |
Customized Teco Model 41H |
0 to 1000 ppmv (~4 ppmv) |
CO2 |
Infrared correlation spectrometer |
LI-COR Li-6262 |
0 to 300 ppmv (0.2 ppmv at 350 ppmv) |
Mass of aerosol and elemental composition
[+] |
25 mm Nuclepore filters/PIXE |
Paulo Artaxo/Vanderlei Martins |
> 10 ug m-3; ~16 elements by PIXE |
Mass of black carbon [+] |
37 mm Teflon filters |
Paulo Artaxo/Vanderlei Martins |
> 1.2 ug m-3 |
Mercury vapor [+] |
Absorption tubes |
Paulo Artaxo/Vanderlei Martins |
> 0.1 ng m-3 |
Particle mass, black carbon (reflectance), trace elements
[+] |
Cascade impactor, MOUDI (PIXE) |
Paulo Artaxo/Vanderlei Martins |
Stages < 0.09, 0.09, 0.18, 0.3, 0.6, 1.0, 1.8 and 3.2 um |